There are two indoor air quality standards in China: one from the Ministry of Health and one from the Ministry of Construction. These are: GB/T18883-2002 and GB50325-2001. National Standard for Indoor Environment 《GB50325-2001》 Pollutant Name Class 1 Construction Projects Class 2 Construction Projects Standard Number Formaldehyde ≤0.08mg/m3 ≤0.12mg/m∧3 GB50325-2001 Benzene ≤0.09mg/m3 ≤0.09mg/m∧3 GB50325-2001 Ammonia ≤0.20mg/m3 ≤0.50mg/m∧3 GB503
There are two indoor air quality standards in China: one from the Ministry of Health and one from the Ministry of Construction.
These are: GB/T18883-2002 and GB50325-2001
National standard for indoor environment GB50325-2001
| Pollutant Name | Class I building projects | Class II building projects | Standard Number |
| Formaldehyde | ≤ 0.08mg/m3 | ≤ 0.12mg/m∧3 | GB50325-2001 |
| Benzene | ≤ 0.09mg/m3 | ≤ 0.09mg/m∧3 | GB50325-2001 |
| Ammonia | ≤ 0.20mg/m3 | ≤ 0.50mg/m∧3 | GB50325-2001 |
| Radon | ≤ 200Bq/m3 | ≤ 400Bq/m∧3 | GB50325-2001 |
| TVOC | ≤ 0.5mg/m3 | ≤ 0.6mg/m∧3 | GB50325-2001 |
Note: Class I buildings: residential buildings, hospitals, elderly apartments, kindergartens, school classrooms, etc.
Class II buildings: office buildings, commercial buildings, hotels, cultural and entertainment venues, bookstores, exhibition halls, libraries, stadiums, public transportation venues, restaurants, barbershops, etc.
National Indoor Environment Standard GB/T18883-2002
| Serial Number | Parameter | Unit | Standard | Remarks: |
| 1 | Formaldehyde | mg/m∧3 | 0.10 | 1-hour average |
| 2 | Ammonia | mg/m∧3 | 0.20 | 1-hour average |
| 3 | Benzene | mg/m∧3 | 0.11 | 1-hour average |
| 4 | Radon | Bq/m∧3 | 400 | Annual average (action level*) |
| 5 | Total Volatile Organic Compounds TVOC | mg/m∧3 | 0.60 | 8-hour average |